Finned Tube Radiators - Data Sheet

DATA SHEET - METRIC OUTPUTS - WATTS PER METRE RUN. STILL AIR 20OC
Tube
Nominal
Bore mm
Fin
Width
mm
Dia Over
Fins
mm
Fin
Pitch
mm
Weight
Per
Foot (kg)
Heating
Surface
m2 per m
MEAN TEMPERATURE OF WATER OC STEAM PRESSURE P.S.I.G
60 65 70 75 80 85 90 95 100 0.2 0.5 1.0 1.5 2.0 2.5 3.0 4.0 5.0 6.0
25 16 65 10 3.81 0.789 165 197 229 259 292 326 357 392 426 453 509 577 632 682 726 764 832 884 936
13 3.46 0.618 149 175 203 231 259 288 320 351 380 406 456 519 569 615 653 687 750 797 843
32 16 73 10 5.06 0.908 212 257 298 341 384 429 473 517 561 597 672 759 833 895 951 999 1086 1151 1218
13 4.58 0.713 202 236 274 310 350 387 428 466 509 540 606 687 753 812 865 908 988 1048 1107
32 16 92 10 6.41 1.691 283 328 373 416 461 505 551 600 648 697 766 863 946 1021 1090 1146 1254 1338 1409
14 5.37 1.170 223 265 306 347 390 433 479 523 570 618 688 782 867 939 1011 1066 1171 1257 1329
40 25.4 98 10 7.18 1.785 312 358 405 452 501 548 599 650 702 758 832 947 1026 1105 1178 1238 1351 1442 1519
14 6.04 1.240 246 289 336 381 425 472 519 567 618 673 746 850 941 1021 1097 1159 1278 1370 1446
50 25.4 108 10 9.18 2.050 360 413 468 522 577 631 691 748 808 870 959 1077 1179 1269 1363 1426 1563 1662 1747
14 7.87 1.426 288 337 388 442 496 549 605 662 721 782 865 985 1088 1180 1267 1336 1465 1571 1663
19 7.22 1.118 247 289 336 380 426 473 519 569 620 673 754 846 934 1011 1086 1146 1259 1350 1427
65 25.4 124 10 11.48 2.361 429 484 548 610 676 740 808 877 948 1020 1123 1260 1380 1488 1585 1666 1816 1937 2038
14 9.88 1.654 336 394 454 513 577 637 702 769 834 903 1000 1136 1254 1360 1461 1540 1691 1816 1917
19 9.08 1.301 288 336 388 440 492 547 602 658 719 779 865 985 1089 1182 1269 1336 1470 1571 1657
80 25.4 137 10 14.13 2.617 466 531 601 671 740 813 884 960 1032 1112 1219 1373 1504 1620 1735 1823 1991 2123 2232
14 12.29 1.837 377 440 505 570 636 704 774 846 920 996 1102 1252 1382 1499 1610 1701 1869 1995 2105
19 11.35 1.447 324 378 433 490 548 606 668 730 793 860 952 989 1196 1297 1394 1473 1614 1730 1821

 

AMBIENT TEMPERATURE CORRECTION.

The emission figures are based on an ambient temperature of 20°C and may be corrected for other ambient temperatures in the range 0°C to 40°C by multiplying by the factor R.

where R = T-Ta
T-20

T = Mean temperature of heating medium °C.
Ta = Ambient Temperature °C.

BANKED TUBE ARRANGEMENTS

When tubes are arranged in banks, the output is obtained by multiplying the output from a single tube by the following factors –

2 TUBE BANK – 1.6 | 3 TUBE BANK – 2.2 | 4 TUBE BANK – 2.8


WATER VELOCITY CORRECTION.

The emission figures for hot water are based on a velocity of 0.30 metres/sec. For other velocities the following factors should be applied.

Velocity
Meters/Sec
0.05 0.10 0.20 0.30 0.40 0.50 0.60 0.80 1.00
Correction
Factor
0.870 0.912 0.965 1.00 1.007 1.017 1.025 1.035 1.040

ENCLOSURE IN CONVECTOR TYPE CASINGS

When tubes are mounted in a suitable convector type casing, outputs are considerable increased. Information can be provided on receipt of details of the proposed casing.